RS-485 Standard Type
| Model Number | ARS-WZ1-N01 | ARS-WZ3-N01 | ARS-WZ1A-N01 | ARS-WZ3A-N01 |
| Measurement Axis | Single-axis (Z) | 3-axis (X, Y, Z) | Single-axis (Z) | 3-axis (X, Y, Z) |
| Frequency Range | 10-1600Hz | 10-1600Hz | 10-5000Hz | 10-5000Hz |
| Power Supply | DC 10-30V | |||
| Power Consumption | 0.5W (at DC 24V) | |||
| Ingress Protection (IP) | IP68 | |||
| Operating Temp (Circuit) | -40°C to +80°C (0% RH – 80% RH) | |||
| Temp Tolerance (Contact) | -40°C to 150°C (Default threshold: 85°C) | |||
| Vibration Velocity (RMS) | Range: 0–50 mm/s | |||
| Accuracy: <1% (@160Hz, 10mm/s) | ||||
| Resolution: 0.1 mm/s | ||||
| Vibration Displacement (P-P) | Range: 0–5,000 μm (Peak-to-Peak) | |||
| Accuracy: <1% (@40Hz, 400μm) | ||||
| Resolution: 0.1 μm | ||||
| Vibration Acceleration (RMS) | Range: 16g (Default g = 9.8 m/s²) | |||
| Accuracy: <1% (@160Hz, 10m/s²) | ||||
| Resolution: 0.1 m/s² | ||||
| Surface Temperature | Default: -40℃ to 85℃ / Customize: -40℃ to 150℃ | |||
| Resolution: 0.1°C | ||||
| Signal Output | RS-485 (Modbus-RTU) | |||
| Housing Material | Main Body: 304 Stainless Steel
Notes: Cable glands and cables utilize optimized materials to ensure signal integrity and protection. Custom material requests are supported.
|
|||
| Housing Style | 1: Type 1 (Integrated external thread at the bottom) | |||
| 2: Type 2 (M5 internal thread at the bottom, convertible to external via accessories) (Optional) | ||||
| Installation Method | M10: M10 External Thread | |||
| M8: M8 External Thread (Optional) | ||||
| M5: M5 External Thread (Optional) | ||||
| CX: Magnetic Suction Mounting (Optional) | ||||
RS-485 Spectrum-Type
| Model Number | ANS-WZ3P-N01 | ANS-WZ3AP-N01 | ANS-WZ1SP-N01 |
| Measurement Axis | 3-Axis (X, Y, Z) | 3-Axis (X, Y, Z) | Single-Axis (Z) |
| Frequency Range | 10-1600Hz | 10-5000Hz | 10-12000Hz |
| Power Supply | DC 10–30V | ||
| Power Consumption | 0.46W | ||
| Ingress Protection (IP) | IP67 | ||
| Operating Temp (Circuit) | -40°C to +80°C (0% RH – 80% RH) | ||
| Temp Tolerance (Contact) | -40°C to 150°C (Default threshold: 85°C) | ||
| Signal Output | RS-485 (Modbus-RTU) | ||
| Vibration Acceleration (RMS) Range | 16g (Default g=9.8m/s²) | 16g (Default g=9.8m/s²) | 100g (Default g=9.8m/s²) |
| Vibration Velocity (RMS) Range | 0–50 mm/s | 0–50 mm/s | 0–199.9 mm/s |
| Vibration Displacement (P-P) Range | 0–5,000 μm | 0–5,000 μm | 0–19,999 μm |
| Surface Temperature | Default: -40℃ to 85℃ / Customize: -40℃ to 150℃ | ||
| Measurement Accuracy | Acceleration: <1% (@160Hz, 10m/s²) | ||
| Velocity: <1% (@160Hz, 10mm/s) | |||
| Displacement: <1% (@40Hz, 400μm) | |||
| Display Resolution | Acceleration: 0.1 m/s² | ||
| Velocity: 0.1 mm/s | |||
| Displacement: 0.1 μm | |||
| Temperature: 0.1°C | |||
| Time-Domain AnalysisTime-Domain Analysis | Acceleration/Velocity: Provides RMS, Peak, and Kurtosis Factor.
Displacement: Provides Peak-to-Peak (P-P) values. |
||
| Frequency-Domain (FFT) | Acceleration Spectrum: Frequency points, band energy, and bearing fault characteristic frequency data.
Velocity Spectrum: Frequency points, band energy, and rotating frequency harmonic energy. |
||
| Alarm Functions | Programmable pre-alerts and alarms for Velocity, Acceleration, and Temperature. | ||
| Mounting Options | Magnetic Base or Threaded Mounting (M5/M8/M10) | ||
| Housing Material | Body: 304 Stainless Steel
Components: Cable glands and specialized cabling designed for signal integrity. Custom materials available on request. |
||
| Housing Style | 1: Type 1 (Integrated external thread at the bottom) | ||
| 2: Type 2 (M5 internal thread at the bottom, convertible to external via accessories) (Optional) | |||
| Installation Method | M10: M10 External Thread | ||
| M8: M8 External Thread (Optional) | |||
| M5: M5 External Thread (Optional) | |||
| CX: Magnetic Suction Mounting (Optional) | |||